Table 3

Diagnostic accuracy of various combinations of measurements to detect ovarian cancer

SensitivitySpecificity
Any (potentially) pathogenic variant (all patients)
Graphic 22 (9 to 43)97 (83 to 100)
Graphic 38 (20 to 59)94 (79 to 99)
Graphic 30 (13 to 53)94 (79 to 99)
Graphic 52 (33 to 71)88 (71 to 96)
(Potentially) pathogenic variants overlapping with the surgical specimen
Graphic 5 (0 to 23)97 (83 to 100)
Graphic 26 (10 to 48)93 (80 to 99)
Graphic 6 (0 to 27)93 (80 to 99)
Graphic 29 (13 to 51)87 (69 to 96)
  • Diagnostic accuracy includes sensitivity and specificity.

  • Values are presented as percentage (95% CI)