TY - JOUR T1 - EP571 Sentinel node mapping in endometrial cancer: analysis of more than 200 cases of hysteroscopic injection of tracers JF - International Journal of Gynecologic Cancer JO - Int J Gynecol Cancer SP - A342 LP - A343 DO - 10.1136/ijgc-2019-ESGO.628 VL - 29 IS - Suppl 4 AU - F Martinelli AU - A Ditto AU - G Bogani AU - U Leone Roberti Maggiore AU - V Chiappa AU - M Evangelista AU - V Liberale AU - F Zanaboni AU - F Raspagliesi Y1 - 2019/11/01 UR - http://ijgc.bmj.com/content/29/Suppl_4/A342.3.abstract N2 - Introduction/Background To report on performance of hysteroscopic-injection of tracers (ICG and Tc99m) for sentinel-nodes (SLNs) mapping in endometrial cancer.Methodology A single center retrospective evaluation of Prospectively collected data of Consecutive patients with endometrial cancer underwent SLNs mapping following hysteroscopic-peritumoral-injection of tracer. Evaluation of Detection Rate (DR) (overall-bilateral-aortic) and diagnostic-accuracy (A) among the entire cohort and comparison between tracers.Results 231 procedures were performed. Mean age:60 years (28–84); mean BMI:27.3 Kg/m2 (15–47). In 164 cases (70.9%) hysterectomy and mapping procedure were performed laparoscopically. The overall-DR of the technique was 94.1% (208/221) (10 cases excluded: 9 equipment failure; 1 vagal reaction). Bilateral pelvic mapping was found in 62.5% of cases (130/208) and was more frequent in the ICG group (73.8% vs 53.3%; p:0.001). In 47.6% of cases (99/208) SLNs mapped both to pelvic and aortic nodes, and in 5 cases (2.5%) only in the aortic area. In 8 patients (3.8%) SLNs were found in aberrant (parametrial/pre-sacral) areas. Mean number of detected SLNs was 3.7 (1–8).26 patients (12.5%) had nodal involvement: 12- (46.2%) macrometastases; 6-(23.1%) micrometastases; 8-(30.7%) ITCs. In 6 cases (23.1%) only aortic nodes were positive; in 6 cases (23.1%) both pelvic and aortic nodes and in 14 cases (53.8%) only pelvic area was involved.Three false-negative results were found, all in the Tc99m group. All had isolated aortic metastases.Overall-sensitivity was 88.5% (95% CI: 71.7–100) and overall-negative-predictive-value (NPV) was 98.4% (95% CI 91.8–100).No differences in terms of overall-DR, overall-sensitivity and overall-NPV were found between the two tracers.Conclusion Hysteroscopic-injection of tracer for SLNs mapping in endometrial cancer is as accurate as cervical injection with a higher DR in the aortic area. ICG improves bilateral DR.Disclosure Nothing to disclose. ER -