Introduction Single port robotic paraaortic lymphadenectomy is challenging surgical procedures. We are to demonstrate the surgical procedures of transperitoneal paraaortic lymphadenectomy.
Description Using bipolar and monopolar instrument of DaVinci SP robotic system, lymph nodes can be removed. With strength of articulating third arm, counter-traction of peritoneum made a clear view of retroperitoneal anatomy. In this video, DaVinci SP robotic paraaortic lymphadenectomy took 48 minutes and removed 15 paraaortic nodes. She discharged home on the next day of surgery without any events.
Conclusion/Implications Left and right infra-mesenteric or infra-renal paraaortic lymphadenectomy can be safely done by SP robotic system In endometrioid endometrial cancer patients.