2022-RA-695-ESGO Comparison of ADNEX model with GI-RADS ultrasonic scoring system in evaluation of adnexal mass
Free
  1. Bindiya Gupta1,
  2. Yasmin Ahmed1,
  3. Anupama Tandon2 and
  4. Priyanka Gogoi3
  1. 1Obstetrics and Gynecology, UCMS and GTB Hospital Delhi, Delhi, India
  2. 2Radiology, UCMS and GTB Hospital Delhi, Delhi, India
  3. 3Pathology, UCMS and GTB Hospital Delhi, Delhi, India

Abstract

Introduction/Background Accurate preoperative diagnosis of adnexal mass helps to estimate the risk of malignancy and enables one to choose the best management approach. Prediction models have been developed to assist clinicians to triage patients to appropriate treatment pathways; and both ADNEX and GI-RADS have shown good accuracy; no study has been done comparing the two systems. The main objective was to evaluate and compare the diagnostic accuracy of Assessment of Different Neoplasias in the Adnexa (ADNEX) Model and Gynecology Imaging Reporting and Data System (GI-RADS) in preoperative assessment of adnexal masses taking histopathology as gold standard.

Methodology In this analytical study, sixty patients more than 14 years of age undergoing surgery for adnexal masses were assessed with transabdominal and transvaginal ultrasound 2–3 days prior to surgery. In cases were surgery was not possible, biopsy was performed to confirm histology. Pregnant women, women with previously established ovarian pathology were excluded. Score probability of the Assessment of Different Neoplasias in the Adnexa (ADNEX) model and Gynaecology Imaging Reporting and Data System (GI-RADS) category was calculated based on the ultrasound parameters of adnexal mass.

Results For ADNEX model sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy was 87.50%, 91.7%, 87.50%, 91.7% and 90.0% respectively. The diagnostic performance of GI-RADS category in terms of sensitivity, specificity, PPV, NPV and accuracy was 95.8%, 61.1%, 62.2%, 95.7% and 75.0% respectively. Overall the diagnostic performance of ADNEX model was better compared to GI-RADS in terms of specificity and positive predictive value with significant difference (p<0.05). The Area under curve (AUC) was 0.957 and 0.919 for ADNEX and GIRADS respectively (p=0.252).

Abstract 2022-RA-695-ESGO Figure 1

Conclusion To conclude, both ADNEX and GI-RADS system had satisfactory diagnostic performances and high negative predictive values. However, the ADNEX model showed better specificity and positive predictive value compared to GI-RADS.